High-Q polymer-coated microspheres for immunosensing applications
Year: 2009
Type: article
Abstract: Homogeneous polymeric thin layers have been used as functionalizing agents on silica microspherical resonators in view of the implementation of an immunosensor. We have characterized the microspheres functionalized with poly-L-lactic acid and Eudragit L100, as an alternative to the commonly used 3-Aminopropyltrimethoxysilane. It is shown that polymeric functionalization does not affect the high quality factor (Q greater than 10(7)) of the silica microspheres, and that the Q factor is about 3 x 10(5) after chemical activation and covalent binding of immunogammaglobulin (IgG). This functionalizing process of the microresonator constitutes a promising step towards the achievement of an ultra sensitive immunosensor.
Source: Optics Express
DOI: 10.1364/oe.17.014694
Language: English
Topic: Photonic and Optical Devices
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,270