A New Method for Distal Repositioning of a Misplaced Esophageal Stent

Year: 2015
Type: article
Abstract: Several techniques for managing migrated and misplaced self-expanding esophageal metal stents have been described.1---5 However, most of these techniques apply only when there is distal stent dislodgment.When there is proximal stent migration or misplacement, and unless there is a lasso at the distal flange, trying to reposition the stent distally through the stenotic tumor can be challenging.Although it may be tried by grasping distal tines with forceps or inflating a dilating balloon within the stent and applying gentle pressure, it seldom results.We herein report an endoscopic approach for an easy and safe reposition of proximal dislodged esophageal metal stents that, as far as we are aware, was never described before.The stent is removed by grasping the lasso on the proximal end of the stent with an alligator jaw grasping forceps.Outside the patient, the lasso is released and the stent is turned upside down.The endoscope is then introduced through the distal end of the stent until the proximal end, where the lasso is re-grasped by the forceps and pulled back, allowing the upper flange of the stent to collapse over the tip of the endoscope (Fig. 1).The body of the stent is generously lubricated with aqueous jelly and stretched along the endoscope.The patient is reintubated with gently passage of the endoscope and the stent through the pharynx
Author: Rui Silva
Institution: IPO Porto
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: diamond
OpenAlex ID: W2005382755
FWCI:
Cites: 5
Cited by:
Related to: 10