A Study of the Determination of Dimensionless Number and its Influence on the Performance of a Combination Wastewater Reactor
Year: 2013
Type: article
Abstract: Dimensionless Peclet number is applied to describe the flow behavior in a specially designed wastewater reactor with compound flow pattern of plug-flow, baffled-flow and mixed-flow. A set of Peclet numbers is obtained for different fluid conditions by measuring the residence time distribution of a tracer in the reactor. Some experiments were made to examine the quantitative influence of on the removal efficiency of COD, NH4+-N and TP, and the results shown that there is an optimum number representing a certain flow pattern at which best removal rates of COD, NH4+-N and TP are obtained.
Source: Procedia Environmental Sciences
Authors: Shiqiang Ding, Lei Liu, Jirun Xu
Institution: Dalian University
Language: English
Subfield: Pollution
Field: Environmental Science
Domain: Physical Sciences
Open Access status: diamond