Work

The Chromatographic Separation of Glycosylated Haemoglobins: A Comparison between Macro- and Micromethods

Year: 1983
Type: article
Abstract: The microchromatographic determination of "fast haemoglobins" is currently used in long-term control of diabetes: its use is made easier by commercially available kits, that are impaired by some analytical variables. For a good standardization of these kits a comparison with an accurate method of analysis is necessary. The macrochromatographic column allows the determination of each fast component with a good precision, and reveals the great complexity of human haemoglobin. Comparison of the two methods shows that the most appropriate temperature of elution for the kit is 20 degrees C and that the increase in the fraction of "fast haemoglobins" in diabetic samples is only related to the HbA1c component.
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2010171191
FWCI: 1.387
Cites: 5
Cited by: 6
Related to: 8