Pharyngo-laryngeal discomfort after breast surgery: Comparison between orotracheal intubation and laryngeal mask
Year: 2008
Type: letter
Abstract: We read with interest and appreciation the article by Radu et al.1Radu A.D. Miled F. Marret E. Vigneau A. Bonnet F. Pharyngo-laryngeal discomfort after breast surgery: comparison between orotracheal intubation and laryngeal mask.Breast. 2008; 17: 407-411Abstract Full Text Full Text PDF PubMed Scopus (17) Google Scholar comparing pharyngo-laryngeal discomfort after breast surgery anesthesia performed with endotracheal tube (ETT) or Classic Laryngeal Mask Airway (cLMA). Their findings appear clinically relevant and strongly consistent with our daily practice. However, we would like to make some comments. The authors report a lower first attempt insertion success rate with cLMA (76.92%) than previously described.2Brimacombe J. Keller C. Fullekrug B. Agrò F. Rosenblatt W. Dierdorf S.F. et al.A multicenter study comparing the ProSeal and Classic laryngeal mask airway in anesthetized, nonparalyzed patients.Anesthesiology. 2002; 96: 289-295Crossref PubMed Scopus (214) Google Scholar, 3Shafik M.T. Bahlman B.U. Hall J.E. Ali M.S. A comparison of the soft seal disposable and the Classic re-usable laryngeal mask airway.Anaesthesia. 2006; 61: 178-181Crossref PubMed Scopus (21) Google Scholar One possible explanation may be the insertion of the cLMA with the cuff not completely deflated as recommended.4Brain A.I.J. Modification of laryngeal mask insertion technique in children.Anesth Analg. 1995; 81: 212PubMed Google Scholar, 5Brimacombe J. Berry A. Brain A.I.J. Optimal intracuff pressure with the laryngeal mask.Br J Anaesth. 1996; 77: 295-296Crossref PubMed Scopus (51) Google Scholar Repeated positioning essays could be responsible for airway morbidity. Second, they report insertion failure in two patients (2 and 4 attempts respectively), but don't explain how they define a failed insertion. Third, cLMA (and ETT) positioning was performed without lubrication: in order to decrease the likelihood of airway morbidity, a water-based gel should always be applied on the dorsal surface of the mask.2Brimacombe J. Keller C. Fullekrug B. Agrò F. Rosenblatt W. Dierdorf S.F. et al.A multicenter study comparing the ProSeal and Classic laryngeal mask airway in anesthetized, nonparalyzed patients.Anesthesiology. 2002; 96: 289-295Crossref PubMed Scopus (214) Google Scholar, 3Shafik M.T. Bahlman B.U. Hall J.E. Ali M.S. A comparison of the soft seal disposable and the Classic re-usable laryngeal mask airway.Anaesthesia. 2006; 61: 178-181Crossref PubMed Scopus (21) Google Scholar Fourth, intracuff pressure was maintained at <25 cm H2O during the procedure. Even if this may minimize pharyngo-laryngeal morbidity, cuff deflation to such low values may be harmful.5Brimacombe J. Berry A. Brain A.I.J. Optimal intracuff pressure with the laryngeal mask.Br J Anaesth. 1996; 77: 295-296Crossref PubMed Scopus (51) Google Scholar A suggested safer approach is to reduce the LMA intracuff pressure to the minimal required to form an effective seal.6LMA™ airway instruction manual.Revised. LMA North America, Inc., San Diego2005Google Scholar All authors disclose any financial and personal relationships with other people or organisations that could inappropriately influence their work. No governmental, departmental, hospital, or institutional funds nor commercial financial support that could influence the work was granted to any of the listed authors.
Source: The Breast
Institutions: University of Padua, Azienda Ospedale - Università Padova
Language: English
Subfield: Anesthesiology and Pain Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,200
OpenAlex ID: W2010414224
