Work

Simple Analytical U-Tube Benchmarks Appropriate for Testing of Pipe-Network Computer Codes

Year: 2002
Type: conference-paper
Abstract: Partially heated U-tube configurations are characteristic idealizations for the so called building condensers of future nuclear reactors with passive safety systems. In this paper three simple cases of natural circulation problems are analyzed and analytical solutions are generated. This solutions are recommended for validation of pipe network computer codes. As an example the procedure is demonstrated for the IVA computer code. The usefulness of the obtained solutions is demonstrated discussing the inherent safety behavior of the building condenser of the Framatome ANP SWR 1000 power plant being under development.
Author: N. I. Kolev
Institution: Framatome (Germany)
Language: English
Field: Energy
Open Access status: diamond
OpenAlex ID: W2017473045
FWCI:
Cites:
Cited by: 5
Related to: 10