Seismic Performance of a Deficient Reinforced Concrete Test Frame with Infill Walls
Year: 2011
Type: article
Abstract: A two‐story, three‐bay RC frame with code incompliant seismic design and detailing is tested using continuous pseudodynamic test method for three scale levels of Düzce ground motion. The ground motion produced minimum, significant, and severe damage states on the test structure. Diagonal cracking of the infill wall, column damage in the form of cover spalling and rebar buckling, and complete disintegration of the infill wall were the important observed damage events for the three scale levels, respectively. Nonlinear time history analyses were able to estimate the story displacement response with reasonable accuracy. The importance of element removal for near collapse damage state is unfolded. Tracing the local engineering demand parameters such as strains and curvature was found to be extremely difficult.
Source: Earthquake Spectra
DOI: 10.1193/1.3609876
Institution: Middle East Technical University
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green