Actinic inspection of extreme ultraviolet programed multilayer defects and cross-comparison measurements
Year: 2006
Type: article
Abstract: The production of defect-free mask blanks remains a key challenge for extreme ultraviolet (EUV) lithography. Integral to this effort is the development and characterization of mask inspection tools that are sensitive enough to detect critical defects with high confidence. Using a single programed-defect mask with a range of buried bump-type defects, the authors report a comparison of measurements made in four different mask inspection tools: one commercial tool using 488nm wavelength illumination, one prototype tool that uses 266nm illumination, and two noncommercial EUV “actinic” inspection tools. The EUV tools include a dark field imaging microscope and a scanning microscope. Their measurements show improving sensitivity with the shorter wavelength non-EUV tool, down to 33nm spherical-equivalent-volume diameter, for defects of this type. Measurements conditions were unique to each tool, with the EUV tools operating at a much slower inspection rate. Several defects observed with EUV inspection were below the detection threshold of the non-EUV tools.
DOI: 10.1116/1.2375085
Authors: Kenneth A. Goldberg, Anton Barty, Yanwei Liu, Patrick Kearney, Yoshihiro Tezuka, Tsuneo Terasawa, John S. Taylor, Hak-Seung Han, Obert R. Wood
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2031900159