Work

Alignment control of GEO 600

Year: 2004
Type: article
Abstract: We give an overview of the automatic mirror alignment system of the gravitational wave detector GEO 600. In order to achieve the required sensitivity of the Michelson interferometer, the axes of interfering beams have to be superimposed with a residual angle of the order 10 −8 rad. The beam spots have to be centred on the mirrors to minimize coupling of alignment noise into longitudinal signals. We present the actual control topology and results from the system in operation, which controls all alignment degrees of the power-recycled Michelson. With this system continuous lock stretches of more than 121 h duration were achieved.
Language: English
Open Access status: bronze
OpenAlex ID: W2052182145
FWCI: 1.345
Cites: 10
Cited by: 26
Related to: 9