Year: 2014
Type: article
Abstract: For an analysis of the horizontal-type geothermal heat exchanger system, an understanding of the ground temperature distributions is required in order to predict system performance. Because it is difficult to decide on the underground temperature due to the adjustment of its temperature cycle, numerous calculations are required in order to decide on the temperature cycle. In this paper, Buggs formula is utilized to decide a phase shift for outdoor temperature and ground surface temperature, which are obtained from Korea Meteorological Administration. Overall, the underground temperature distribution in the Changwon region is predicted as $10.5^{\circ}C{\sim}20.3^{\circ}C$ at a depth of 3 m.
Source: 설비공학논문집
Authors: Sung Woo Cho, Pyeong Chan Ihm
Institution: Dong-A University
Language: English
Field: Energy
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W2052250810