Year: 1997
Type: article
Abstract: Aim of nebuliser therapywhen determining the fill volume required to deliver a drug to a patient.9 The aim of nebuliser therapy is to deliver a therapeutic dose of the desired drug in the form Fill volume: the volume of drug solution initially put into the nebuliser chamber.It must exceed of an aerosol of respirable particles within a fairly short period of time, usually the residual volume by a sufficient amount to provide therapeutic benefit to the patient.9 It is 5-15 minutes.To achieve this, nebuliser systems should be expected to provide a drug suggested that it should be at least twice the residual volume.It is important to be aware output with about 50% of the particles below 5.0 m mass median diameter.It is important of the desirable fill volume when prescribing nebuliser drugs in prepackaged ampoules.to obtain an acceptable range of aerosol particle sizes because of the way in which these areThe definitions of aerosol output, respirable particles, mass median diameter (MMD), mass deposited in the tracheobronchial tree.[1][2][3][4][5] median aerodynamic diameter (MMAD), respirable output, and respirable fraction are given in the paper by O'Callaghan and Barry Practical definitions on page S35.Jet nebuliser: a nebulising chamber where an aerosol is generated from a flow of gas from an electrical compressor or from a compressed gas supply (air or oxygen).The gas passes through Factors affecting nebuliser performanceThe general term "nebuliser" usually implies a very small hole (the jet or Venturi) resulting in liquid being sucked up through the small the combination of the nebuliser chamber and the compressor.Jet nebulisers usually have a hole from the chamber base and atomised.The resultant large particles then impact upon constant output, but to prevent wastage new breath-enhanced nebulisers are available where baffles to generate small respirable particles.6 Ultrasonic nebuliser: an electrically driven sys-the output is enhanced in the inhalation phase.Ultrasonic nebulisers are effective but are less tem whereby a rapidly vibrating piezoelectric crystal vibrates the drug solution and produces robust and more expensive than jet nebuliser systems and are generally not used for regular aerosol particles of a respirable size.6 Flow rate through the nebuliser: the flow rate domiciliary therapy.The major use of nebuliser systems is to of gas, whether from a compressed source or from a compressor, that actually drives the deliver bronchodilator therapy.The specification of the nebuliser chamber for ad-nebuliser chamber.It is not the same as the flow rate from the compressor which will often ministering bronchodilators is different from that required to deliver other drugs such as be considerably higher.7 It is obtained by producing a pressure-flow rate curve for the nebu-antibiotics or pentamidine.The output of a nebuliser is determined by liser.Recordings of circuit pressure are made from zero flow (maximum pressure) to max-a combination of factors which must be taken into account, and will depend on (1) the design imum flow (minimum pressure) using a rotameter, a compressor unit (or flow generator), of the nebuliser chamber, 6 (2) the flow of the driving gas and the performance characteristics and pressure measuring device.By substituting the nebuliser chamber for the rotameter the of the compressor, 7 10 11 (3) the volume of solution (fill volume) of the drug at the start of nebu-pressure in the circuit can be obtained with a Respiratory Department, constant flow rate from the flow generator.lisation, 9 12 (4) the time taken to nebulise the Bristol RoyalFrom the pressure-flow curve the flow rate at solution of drug, 7 9 (5) the viscosity, surface ten-Infirmary, the nebuliser can be obtained.7 sion, and concentration of the drug solution, 13 Bristol BS2 8HW, UKVolume output from the nebuliser: the volume of (6) the residual volume, 9 and (7) tapping of the A H Kendrick solution leaving the nebuliser chamber.Whilst nebuliser chamber during nebulisation.Department of useful as a general guide to nebuliser per-The volume output and particle size of water, Medicine, formance, it does not give precise information saline, salbutamol, terbutaline, and iprac/o Respiratory Department, about the actual drug output.2 tropium bromide are similar.14 For more vis-Bristol Royal Drug output from the nebuliser: the actual cous solutions the volume output is much Infirmary, amount of drug that is released during nebu-slower (fig 1).13 15 The output of steroids may Bristol BS2 8HW, UK E C Smith lisation.Because of a variety of factors, in-be similar to salbutamol although the drug is cluding evaporation, a precise measure of drug a suspension.However, the volume output Department of output (as opposed to volume output) must be from a nebuliser is not directly related to the Respiratory Medicine, Royal Shrewsbury assessed using marker techniques.8 drug output, 8 and the drug output and its Hospitals NHS Trust, Residual volume: the volume of solution left availability are different between broncho-Shrewsbury SY3 8XQ, in a nebuliser chamber once nebulisation has dilators, antibiotics, and steroids.Measuring UK R S E Wilson ceased and all of the aerosol particles have been volume output is simple and provides a guide to the performance of nebuliser/compressor generated and have left the nebuliser chamber.
Source: Thorax
Authors: A. H. Kendrick, E. C. Smith, R. S. Wilson
Institution: Bristol Royal Infirmary
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W2099541007