Work

Evaluation of the efect of EDTA, EGTA and CDTA on dentin adhesiveness and microleakage with different root canal sealers

Year: 2002
Type: article
Abstract: The effect of chelating solutions EDTA, EGTA and CDTA on human dentin adhesiveness and microleakage with 4 sealers (Sealer 26, Sealapex, N-Rickert and Endofill) was evaluated in vitro. Whether or not there was a mathematical correlation between the tests of adhesiveness and microleakage was also evaluated. A total of eighty maxillary and mandibular molars were used to test adhesiveness. After wearing of the occlusal surface to obtain a flat surface, the sealer was placed with an aluminum cylinder (10 mm x 6 mm). Adhesiveness was evaluated with a 4444 Instron universal testing machine. Microleakage was evaluated in 160 maxillary canines after root canal instrumentation, obturation and clearing. The penetration of India ink in the apical region was measured with a measurescope. The teeth were divided into 4 groups: group 1, distilled water, group 2, EDTA; group 3, EGTA; group 4, CDTA. Sealer 26 and EDTA had the best results (p<0.01) for adhesiveness and microleakage. There was no correlation between the test for adhesiveness and microleakage.
Language: English
Subfield: Oral Surgery
Field: Dentistry
Open Access status: gold
Estimated APC paid: $104
OpenAlex ID: W2148758693
FWCI: 1.913
Cites: 18
Cited by: 44
Related to: 10