Work

Cable Crosstalk Suppression in Resistive Sensor Array with 2-Wire S-NSDE-EP Method

Year: 2016
Type: article
Abstract: With long flexible cables connected to the 1-wire setting non-scanned-driving-electrode equipotential (S-NSDE-EP) circuit, the resistive sensor array modules got flexibility in robotic operations but suffered from the crosstalk problem caused by wire resistances and contacted resistances of the cables. Firstly, we designed a new S-NSDE-EP circuit using two wires for every driving-electrode and every sampling-electrode to reduce the crosstalk caused by the connected cables in the 2D networked resistive sensor array. Then, an equivalent resistance expression of the element being tested (EBT) for this circuit was analytically derived. Then, the 1-wire S-NSDE-EP circuit and the 2-wire S-NSDE-EP circuit were evaluated by simulations. The simulation results show that the 2-wire S-NSDE-EP circuit, though it requires a large number of wires, can greatly reduce the crosstalk error caused by wire resistances and contacted resistances of the cables in the 2D networked resistive sensor array.
Language: English
Subfield: Instrumentation
Open Access status: hybrid
Estimated APC paid: $2,830
OpenAlex ID: W2285930833
FWCI: 4.659
Cites: 20
Cited by: 19
Related to: 10