Year: 1993
Type: article
Abstract: Wind-induced internal pressures in buildings were analytically evaluated by using external pressure coefficients of six typical building models. The overall building porosity and the specific wall openings were taken into consideration in the evaluation. The analytical approach was based on the balance of flow through the openings. The evaluation results show that the mean internal pressure coefficients are the values ranging from -0.4 to 0.0 for the all walls equally permeable buildings. For the non-equally permeable buildings, the relations between the mean internal pressure coefficient and the opening ratio are shown in this paper.
Source: Wind Engineers JAWE
Authors: Noriko CHINO, Hisashi OKADA
Language: English
Topic: Wind and Air Flow Studies
Subfield: Environmental Engineering
Field: Environmental Science
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2312376722