Work

Reliability Evaluation of a Motor Core Applied Ultrasound Infrared Thermography Technique

Year: 2016
Type: article
Abstract: This study used an ultrasound infrared thermography technique to detect issues in the motor core of typical power equipment. The current defect inspection method of the motor core is often incomplete (due to the limits of visual inspection) and thus the reliability of the motor core is reduced. Therefore, in this study, experiments were carried out to increase the reliability of the test by using an ultrasonic infrared thermal non-destructive inspection method to image the motor core. The ambient temperature of the experimental system was maintained at $25^{\circ}C$ . Experiments were carried out to examine a damaged motor core and a defect-free motor core. Experimental results confirm the technique clearly detected defects in the motor core, thereby confirming the possibility of using this technique in the field.
Institution: Chosun University
Language: English
Open Access status: bronze
OpenAlex ID: W2525632517
FWCI: 0.822
Cites: 8
Cited by: 5
Related to: 10