Stochastic Momentum Cooling Experiments with a Barrier Bucket Cavity and Internal Targets at COSY-Jülich in Preparation for HESR at FAIR
Year: 2010
Type: conference-paper
Abstract: Numerical studies of longitudinal filter and time-of-flight (TOF) cooling suggest that the strong mean energy loss due to an internal Pellet target in the High Energy Storage Ring (HESR) at the FAIR facility can be compensated by cooling and operation of a barrier bucket (BB) cavity. In this contribution detailed experiments at COSY to compensate the mean energy loss are presented. The internal Pellet target was similar to that being used by the PANDA experiment at the HESR. A BB cavity was operated and either TOF or filter stochastic momentum cooling was applied to cool a proton beam. Experimental comparisons between the filter and TOF cooling method are discussed. Measurements to determine the mean energy loss which is used in the simulation codes are outlined. The experiments proved that the mean energy loss can be compensated with a BB cavity. Results are compared with numerical tracking simulations which include the synchrotron motion in a barrier bucket as well as in an h = 1 cavity and stochastic momentum cooling. A detailed discussion of the tracking simulation code will be outlined in a separate contribution to this conference.
Source: JACOW
Language: English
Subfield: Nuclear and High Energy Physics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W2557798511