Improved estimation of the left ventricular ejection fraction using a combination of independent automated segmentation results in cardiovascular magnetic resonance imaging
Year: 2014
Type: preprint
Abstract: —This work aimed at combining different segmenta-tion approaches to produce a robust and accurate segmentation result. Three to five segmentation results of the left ventricle were combined using the STAPLE algorithm and the reliability of the resulting segmentation was evaluated in comparison with the result of each individual segmentation method. This comparison was performed using a supervised approach based on a reference method. Then, we used an unsupervised statistical evaluation, the extended Regression Without Truth (eRWT) that ranks different methods according to their accuracy in estimating a specific biomarker in a population. The segmentation accuracy was evaluated by focusing on the left ventricular ejection fraction (LVEF) estimate resulting from the LV contour delineation using a public cardiac cine MRI database. Eight different segmentation methods, including three expert delineations, were studied, and sixteen combinations of the five automated methods were investigated. The supervised and unsupervised evaluations demonstrated that in most cases, STAPLE results provided better estimates of the LVEF than individual automated segmentation methods. In addition, LVEF obtained with STAPLE were within inter-expert variability. Overall, combining different automated segmentation methods improved the reliability of the segmenta-tion result compared to that obtained using an individual method
Source: HAL
Authors: Lebenberg, Jessica, Lalande, Alain, Clarysse, Patrick, Buvat, Irène, Casta, Christopher, Cochet, Alexandre, Constantinides, Constantin, Cousty, Jean, de Cesare, Alain, Jehan-Besson, Stéphanie, Lefort, Muriel, Najman, Laurent, Roullot, Elodie, Sarry, Laurent, Tilmant, Christophe, Frouin, Frédérique, Garreau, Mireille
Institutions: Pitié-Salpêtrière Hospital, Université Pierre-et-Marie-Curie, Laboratoire d'Imagerie Fonctionnelle, Inserm, Université de Bourgogne, Laboratoire d’Électronique, Informatique et Image, Centre National de la Recherche Scientifique, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé, Université de Clermont I, ESME - École d’ingénieurs pluridisciplinaires, Laboratoire d'Informatique Gaspard-Monge, Université Paris-Est Marne-la-Vallée, Institut Pascal, Laboratoire Traitement du Signal et de l'Image
Language: English
Subfield: Computer Vision and Pattern Recognition
Field: Computer Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W2624256215
