Aqueous shunts for glaucoma
Year: 2017
Type: review
Abstract: BACKGROUND: Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. OBJECTIVES: To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. SELECTION CRITERIA: We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. DATA COLLECTION AND ANALYSIS: Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. MAIN RESULTS: Baerveldt; and 3 trials of Molteno implants (single-plate with oral corticosteroids versus single-plate without oral corticosteroids, 1 trial; double-plate versus single-plate, 1 trial; and pressure-ridge versus double-plate with tube ligation, 1 trial). AUTHORS' CONCLUSIONS: Information was insufficient to conclude whether there are differences between aqueous shunts and trabeculectomy for glaucoma treatment. While the Baerveldt implant may lower IOP more than the Ahmed implant, the evidence was of moderate-certainty and it is unclear whether the difference in IOP reduction is clinically significant. Overall, methodology and data quality among existing randomized controlled trials of aqueous shunts was heterogeneous across studies, and there are no well-justified or widely accepted generalizations about the superiority of one surgical procedure or device over another.
Institution: University of California, Los Angeles
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Open Access status: green
Funder: National Eye Institute
OpenAlex ID: W2740932115