Work

Method Development and Validation of Valsartan and Its Impurities by High Performance Liquid Chromatography

Year: 2017
Type: article
Abstract: Our main objective is to develop an accurate and precise HPLC method for the determination of valsartan and its impurities. An inertsil ODS-3v; (150 × 4.6) mm; 5 μm column is used for the Separation of drugs. The flow rate was maintained at 1.0 mL/min and the wave length used for detection was 230 nm. The linearity was observed in the range of 0.025–50μg/ml of spiked impurities in valsartan, impurity B and impurity C with a correlation coefficient of 0.990, 0.996 and 0.997 respectively. Linearity, accuracy, precision and robustness parameters for the suggested method were estimated for validation. The developed method can be utilized in the analysis of valsartan tablets.
Language: English
Field: Chemistry
Open Access status: hybrid
OpenAlex ID: W2742467406
FWCI:
Cites:
Cited by: 7
Related to: 10