Year: 2017
Type: conference-paper
Abstract: An inductively coupled plasma reactor driven by continuous wave (cw) or pulse source with dc bias is introduced to investigate the plasma parameters and ion energy distributions using COMSOL and compared with experimental results. The results show that with the increase of pressure, the electron density varies from 4.5 × 10 11 cm -3 to 16.7 × 10 11 cm -3 , and electron temperature is in the range of 3.3eV to 3.9eV. For pulsed power, the change of electron temperature is corresponding to the duty cycle of pulse power. With the dc bias, the ion energy peaks shift from 8eV to 19.5eV, and the full width at half maximum (FWHM) of the IEDs varies in the range of 0.5eV to 2.7eV. Finally, application of a synchronous dc bias in the afterglow of pulsed plasma leads to a bi-modal IEDs with a sharper peaks at lower energy during the afterglow and a broader peak at higher energy when the power is on.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W2780901262