VMAT-SIB treatment Auto-Planning for breast with locoregional lymph nodes in breathhold
Year: 2018
Type: conference-abstract
Abstract: ESTRO 37 S600 minimum requirements for each investigational arm.4DCT and 3DCBCT are mandated.IMRT is encouraged throughout all of the arms, except for Isotoxic IMRT, where it is mandated.A minimum of imaging on fractions 1-3 and then weekly is required.Isotoxic IMRT arm mandates per fraction imaging.Gating techniques are optional. ResultsBetween January and May 2016, 32 FQ were returned (80%).The results are shown in table 1. 28 centres will use 4DCT and 3 centres are commissioning it.Only 1 centre will need to implement 4DCT.IMRT and VMAT are used for lung patients in 17/32 centres.7 centres will implement IMRT.The majority (27/32) uses 3DCBCT and 6/27 centres , have implemented 4D-CBCT for a selection of patients.2 centres will implement 3DCBCT to join the trial.Participation in ADSCaN will require the implementation of per-fraction imaging in 13 centres.This represents only a change in the frequency of treatment imaging in all centres, which are already performing imaging as part of local protocols, and was therefore considered a minor change in clinical practice.Overall 7 centres out of 32 will implement new techniques to participate in ADSCaN.
Source: Radiotherapy and Oncology
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $3,770
OpenAlex ID: W2808768971