Effects and Characteristics of AC Interference on Parallel Underground Pipelines Caused by an AC Electrified Railway
Year: 2018
Type: article
Abstract: An AC electrified railway can interfere significantly with parallel underground pipelines in a public transportation corridor. Such interference may threaten the long-term transportation and the operational safety of the pipelines. Therefore, this paper presents a mathematical model to illustrate the electromagnetic coupling between an AC electrified railway and nearby parallel underground pipelines. As the basis of the engineering calculation, an integration simulation model based on CDEGS software, which included an electrified railway and pipeline system, was built and its correctness was validated by comparing it with a mathematical model. Also, the effects of electric traction load parameters, pipeline parameters, and soil structure parameters were analyzed, the results of which demonstrate the distribution characteristics of AC interference on parallel underground pipelines. Using a real case in China as an example, protection measures were introduced to decrease coupling interference and their effectiveness was verified by simulation calculations and field measurements.
Source: Energies
DOI: 10.3390/en11092255
Authors: Minwu Chen, Siyang Liu, Jiuguo Zhu, Chonghao Xie, Hang Tian, Jianjun Li
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,137
Awards: G2401276309, G7941634177
OpenAlex ID: W2889249257