Work

The Development of a Nw Fast Harmonic Kicker for the JLEIC Circulator Cooling Ring

Year: 2018
Type: conference-paper
Abstract: After the first half-scale, 5 harmonic kicker cavity prototyping * for the JLEIC's CCR/ERL electron cooler and the beam dynamic simulation study of the 10-turn CCR **. The optimized circulation cooling turns has been changed to 11 and only 5 odd-harmonic modes from 86.6 MHz to 779.4 MHz plus a DC bias are needed for the harmonic RF kicker system. The new cavity design including the electromagnetic and thermal cooling optimization and its 11 turns beam bunch tracking simulation with the new numerology of RF deflecting voltages will be presented. Further design specifications for its RF harmonic drive and the broadband RF window, coupler and circulator component will be given for handling 5 kW of total RF power.
Source: JACOW
Language: English
Open Access status: hybrid
OpenAlex ID: W2919970008
FWCI: 2.914
Cites:
Cited by: 5
Related to: 9