Year: 2010
Type: dissertation
Abstract: There is currently no traceable power sensor for millimetre wave frequencies above 110 GHz. This thesis investigates a novel approach to remove this limitation by combining the placement of a uniquely designed microchip directly in waveguide. The design of the chip is novel in that it does not rely on a supporting structure or an external antenna when placed in the waveguide. The performance of the design was primarily analysed by computer simulation and verified with the measurement of a scale model. The results show that it is feasible to measure high frequency power by placing a chip directly in waveguide. It is predicted that the chip is able to absorb approximately 60% of incident power. Any further efficiency would require modification of the chip substrate. However, this proposed design should allow the standards institutes a reference that will enable the calibration of equipment to beyond 110 GHz.
Author: Mark Hedley Jones
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W29293320