Comparative one-month safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation
Year: 2019
Type: article
Abstract: Transcatheter aortic valve implantation (TAVI) for aortic stenosis is becoming an appealing alternative to surgical aortic valve replacement in high-risk patients and to medical therapy for inoperable ones. Several new-generation TAVI devices have been recently introduced, but comparative analyses are lacking. We aimed to compare 1-month outcomes associated with such five leading new-generation TAVI devices exploiting data collected in the prospective observational RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) Study. We queried the dataset of the ongoing RISPEVA study to retrieve baseline, procedural and 1-month outcome details of patients undergoing TAVI with Acurate, Evolut, Portico, Lotus, and Sapien3. Analysis was based on unadjusted and propensity score-adjusted methods. We included 1976 patients, 234 (11.8%) treated with Acurate, 703 (35.6%) with Evolut, 151 (7.6%) with Lotus, 347 (17.6%) with Portico, and 541 (27.4%) with Sapien3. Unadjusted analysis for baseline features highlighted several significant differences, and other discrepancies were found for procedural features. Despite these differences, device and procedural success were similarly high (ranging from 98.0% to 99.4%, p > 0.05). However, procedural valve migration appeared more common with Acurate (p = 0.007), and major bleeding with Sapien3 (p = 0.002). Unadjusted analysis for 1-month outcomes also highlighted significant differences in the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure (favoring Portico, p < 0.001), major vascular complications (favoring Lotus, p < 0.001), renal failure (favoring Portico, p = 0.035), and permanent pacemaker implantation (favoring Acurate, p < 0.001). Propensity score-adjusted analyses showed lower rates of major adverse events with Evolut and Portico (p < 0.05), major vascular complications with Lotus and Portico (p < 0.05), renal failure with Sapien3 (p < 0.05) and permanent pacemaker implantation with Acurate (p < 0.05). In conclusion, new-generation TAVI devices have different profiles of early comparative safety and efficacy. These findings should be taken into account for individualized decision making and patient management.
Source: Scientific Reports
Authors: Arturo Giordano, Nicola Corcione, Paolo Ferraro, Alberto Morello, Sirio Conte, Luca Testa, Francesco Bedogni, Alessandro Iadanza, Sergio Berti, Damiano Regazzoli, Enrico Romagnoli, Carlo Trani, Francesco Burzotta, Martino Pepe, Giacomo Frati, Giuseppe Biondi-Zoccai, The Registro Italiano GISE sull’impianto di Valvola Aortica Percutanea (RISPEVA) Study Investigators, Corrado Tamburino, Federica Ettori, Anna Sonia Petronio, Mauro Rinaldi, Silvio Klugmann, Paolo Rubino, Elena Tremoli, Alfredo Marchese, Gennaro Sardella, Gianfranco Pistis, Elvis Brscic, Pietro Giudice, Luigi Piatti, Diego Ardissino, Ciro Indolfi, Francesco Chiarella, Maurizio Tespili, Stefano De Servi, Roberto Bonmassari, Antonio Fappani, Claudio Cuccia, Alberto Cremonesi, Fabrizio Tomai
Institutions: IRCCS Policlinico San Donato, Ospedale Santa Maria alle Scotte, Humanitas University, Università Cattolica del Sacro Cuore, Agostino Gemelli University Polyclinic, University of Bari Aldo Moro, Istituto Neurologico Mediterraneo, Sapienza University of Rome, Clinica Mediterranea, University of Catania, Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia, University of Pisa, University of Turin, Azienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Centro Cardiologico Monzino, Policlinico Umberto I, Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo, AOU San Giovanni di Dio e Ruggi d'Aragona, Alessandro Manzoni Hospital, Ospedale di Parma, Azienda Ospedaliero-Universitaria "Renato Dulbecco", Ospedale Policlinico San Martino, Azienda Ospedaliera Bolognini Seriate, Azienda Ospedaliera Ospedale Civile di Legnano, Ospedale Santa Chiara, Fondazione Poliambulanza Istituto Ospedaliero, Maria Cecilia Hospital, European Hospital
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,790
Funder: Edwards Lifesciences
OpenAlex ID: W2990937183