Work

Significant improvement in data quality with simplified SCRB-seq

Year: 2020
Type: article
Abstract: The ability to interrogate the transcriptomes of single cells with single-cell RNA-seq has transformed our view of a population of cells. Likewise, rather than interpreting results from a single population averaged cell type, the population response is now often described in terms of inherently different cell phenotypes, including those that are rare [1,2]. Thus, a key application of single-cell RNA-seq is to identify rare and new cell types otherwise undetected in the population, which forms the basis of their popularity in a wide range of studies of fundamental cellular processes including development, tissue function, and progression of diseases such as cancer. Clearly, an accurate characterization of the transcriptional status within the individual cells is absolutely essential in this analysis. Still, the fluctuations in gene counts that are measured in typical single-cell RNA-seq studies are nonetheless often greater than those observed in population-level RNA-seq studies [3]. This technical variation in single-cell RNA-seq experiments could lead to lowered detection sensitivity or incorrect assignments. In many of the present single-cell RNA-seq methods, there is indeed still room for improvement. One of the most powerful of these methods is single-cell RNA barcoding and sequencing (SCRB-seq [4]). With SCRB-seq, single cells are individually localized within 96/384-well plates using fluorescence-activated cell sorting and so are highly flexible with cell number and with no limitation on cell size. In order to increase the reaction efficiency and realize an unbiased quantitative analysis of transcripts, cell barcodes and unique molecular identifiers (UMIs) are introduced during the template-switching reverse transcription, which makes it possible to amplify and purify the pooled cDNA together and thus construct a single library for the entire sample at once. Compared with other single-cell transcriptome technologies, SCRB-seq has unique advantages such as being exceedingly low-cost, with simple steps and high throughput that can be completed with conventional equipment available in most laboratories. The use of UMIs reduces potential biases from polymerase chain reaction amplifications and improves the quantitative analysis of single-cell states. Thus, there is indeed a tremendous potential for the broad application of this method by many researchers in single-cell RNA characterizations. However, we find that there is a significant technical limitation with this protocol. We first examined the lengths of cDNA generated with the standard assay from 48 individual 3T3 cells. We found that there is a wide distribution of fragments below 500 bp, with only 23% with a length greater than 1000 bp (Fig. 1A). This is far below the ~50% observed by others using different single-cell RNA-seq methods [5]. Clearly, this step of the protocol should be improved to make this method sufficiently robust. We noted that proteinase K was introduced to degrade ubiquitous RNases for the purpose of protecting the integrity of RNA. However, the subsequent exposure to high temperatures (95°C) required to inactivate the proteinase K might have had the opposite effect: it might have caused the degradation of RNA. Therefore, we examined the effect of such high-temperature incubations on purified total RNA. We indeed found that, following incubation at 95°C either for 20 min as in the original SCRB-seq protocol (during which the solution was completely evaporated to readjust concentrations in the later steps) or 15 min (where sufficient amount of solution also evaporated), the integrity of RNA is significantly decreased (Fig. 1B). However, when the incubation temperature was reduced to 70°C for 15 min, which also led to sufficient volume reduction of the solution, the integrity of RNA is maintained (Fig. 1B). Consistent with these observations, reverse transcription of purified RNA that was incubated at 95°C for 15 min resulted in only 5% of cDNA that was longer than 1000 bp, with a wide distribution of fragments below 500 bp (Fig. 1C). By contrast, with 70°C incubation, there was more than 52% of the cDNA that was longer than 1000 bp (Fig. 1D). The effect of temperature on RNA quality and lengths of the cDNA at different steps in the SCRB-seq method (A) Lengths of cDNA generated from 3T3 cells using the original SCRB-seq protocol. (B) The integrity of collected RNA following heating at 95°C for 20 min (where the solution fully evaporated), 15 min (with partial evaporation), and at 70°C for 15 min (with partial evaporation) measured with Agilent Bioanalyzer 2100 (Santa Clara, USA). Shown are results for three replicates for each case. (C) Lengths of cDNA generated from RNA following incubation at 95°C for 15 min prior to reverse transcription. (D) Lengths of cDNA generated from RNA following reverse transcription but with 70°C incubation. The effect of temperature on RNA quality and lengths of the cDNA at different steps in the SCRB-seq method (A) Lengths of cDNA generated from 3T3 cells using the original SCRB-seq protocol. (B) The integrity of collected RNA following heating at 95°C for 20 min (where the solution fully evaporated), 15 min (with partial evaporation), and at 70°C for 15 min (with partial evaporation) measured with Agilent Bioanalyzer 2100 (Santa Clara, USA). Shown are results for three replicates for each case. (C) Lengths of cDNA generated from RNA following incubation at 95°C for 15 min prior to reverse transcription. (D) Lengths of cDNA generated from RNA following reverse transcription but with 70°C incubation. Significant improvement in the lengths of cDNA generated, numbers of detected genes and transcriptional variability from single 3T3 cells by the simplified method (A) Lengths of cDNA obtained from 3T3 cells using the simplified method. (B) The detected number of genes using SCRB-seq and the simplified SCRB-seq. (C) The correlation in gene expression values between all pair-wise combinations of single cells using the two methods. (D) The transcriptional variability within the cells treated by the two methods. Significant improvement in the lengths of cDNA generated, numbers of detected genes and transcriptional variability from single 3T3 cells by the simplified method (A) Lengths of cDNA obtained from 3T3 cells using the simplified method. (B) The detected number of genes using SCRB-seq and the simplified SCRB-seq. (C) The correlation in gene expression values between all pair-wise combinations of single cells using the two methods. (D) The transcriptional variability within the cells treated by the two methods. The above results strongly imply that incubation at 95°C might have caused serious degradation of RNA. Yet, the inactivation of proteinase K was also required for the subsequent steps to proceed. Therefore, the only option is to completely avoid the proteinase K treatment and rely solely upon the RNase inhibitors to protect the RNA until reverse transcription is completed. To reduce the reaction volume in order to facilitate the execution of subsequent steps, we therefore incubated the sample at 70°C, which accelerates evaporation, as we have shown that under this condition, several minutes of incubation does not lead to extensive loss of RNA. Furthermore, barcode primers are also pre-added to the collection buffer to minimize the time required for these steps. We found that, by using this simplified SCRB-seq protocol, the proportion of cDNA with length greater than 1000 bp is increased significantly. This is seen by comparing Fig. 2A with Fig. 1A: with the new procedure, the fraction of cDNA that is longer than 1000 bp is 54%, which is more than twice the standard SCRB-seq protocol (Fig. 1A). We expected that with such a significant improvement in RNA quality, the number of genes detectable per cell should improve accordingly, especially those genes with low expression levels. To test this, we prepared a library of 96 cells following this simplified SCRB-seq method. As a comparison, we also prepared a library of 48 cells with the standard SCRB-seq. For the former, we obtained 38.4 M valid reads (0.4 M reads/cell). For the latter, 33.6 M valid reads were obtained (0.7 M reads/cell). To compare the results, we normalized the valid reads to the same level (0.4 M per cell). The results are shown in Fig. 2B: 4895 genes were detected per cell by the simplified SCRB-seq protocol compared with only 2883 genes with the standard SCRB-seq, which is an impressive 70% increase. Finally, to examine the practical consequences on single-cell characterizations of this increased number of detected genes, we also quantified the extent to which the individual cell transcriptomes generated by either the standard or simplified SCRB-seq were correlated. This analysis showed that, overall, there was a substantially greater number of cells that were more highly correlated in the simplified method (Fig. 2C; P < 10−300). Therefore, as we expected, improving RNA quality in the early steps of this procedure directly impacted the consistency between individual cells in the same batch. Such improvements should be invaluable for the analysis of consequential stochastic expression within an isogenic population of cells or for the identification of rare cell types in a heterogeneous cell population. Such improvements should also improve the quality of the reconstructed expression landscape of identified phenotypes. To further quantify this variability, we examined the intrinsic transcriptional variability. To this end, we assumed that a correlation coefficient of one reflects pairs of cells that do not exhibit any intrinsic cell transcriptional variability, and thus defined the inter-cell variability for a given cell pair as the difference in correlation coefficient between no variability (that is, one) and their measured correlation coefficient. Measuring all pair-wise combinations, we found that cells examined with the standard SCRB-seq protocol exhibited a mean variability of 41% while those with the simplified method yielded a significantly lower variability of 16% (Fig. 2D and Supplementary Fig. S1; P < 10−300). Therefore, the detected inter-cell variability decreased by over half with our simplification. In summary, the low cost and ready availability of the equipment necessary to perform the SCRB-seq assay distinguishes this method from other single-cell RNA-seq techniques [6–8] and makes it one of the most potentially transformative in the field. Our results with the simplified SCRB-seq clearly indicates that the protection of the RNA quality is perhaps the most critical step in the entire protocol and must be carefully optimized, regardless of the specifics of the library preparation. By maintaining the integrity of the single-cell RNA with this simple modification, we reduce the major source of the transcriptional noise otherwise present in the experiment, enabling a more accurate depiction of the differences and similarities between different individual cells and a more effective detection of rare phenotypes in heterogeneous populations. This work was supported by the grants from the National Natural Science Foundation of China (Nos. 2018YFC1003500, 81972909, 31971151, and 11374207), the Open Large Infrastructure Research of Chinese Academy of Sciences (No. 18H100000104), the Cross Research Fund of Biomedical Engineering at Shanghai Jiao Tong University (Nos. YG2017MS75 and YG2016MS46), and the K. C. Wong Education Foundation (H.K.).
Language: English
Open Access status: bronze
OpenAlex ID: W3010678317
FWCI: 0.385
Cites: 8
Cited by: 8
Related to: 10