Abstract: This study presents results from laboratory measurements of mineral wool insulated steel sandwich panels. The purpose of the work was to have a better understanding on the heat and moisture conditions inside sandwich panels and to study how the structure behaves in water leakage situation. The tests were done by sealing the structure from all sides and regulating the temperature on one side of the test structure while measuring the temperature and relative humidity conditions inside the structure. Water leakages were created by injecting liquid water onto the insulation layer. According to the results, water vapour pressure differences stayed relatively small both in stationary and dynamic conditions. This implies that the limiting factor for moisture source was the evaporation rate from the water leakage and that the vapour pressure throughout the insulation layer is determined strongly by the vapour pressure at the possible condensation layer. The paper discusses also the determination of sensor accuracy and impacts of a thermal bridge from the probe itself. Also, measurement results from a new radio wave monitoring method are presented.
Source: E3S Web of Conferences
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
Awards: G1888088267, G1953887145, G2628364946, G2975900969, Establishment of Smart City Center of Excellence, G4766346274, G4937468798, G5145168321, G5611342602, G5782242854, G6030292166, G6601552843, G704183748, G7689385337, Moisture safety of interior insulation, constructional moisture and thermally efficient building envelope
OpenAlex ID: W3040468277