Work

An endothelial rejection line following Descemet stripping automated endothelial keratoplasty

Year: 2020
Type: article
Study design: Case Report
Abstract: BACKGROUND: The endothelial rejection line is rarely seen after Descemet stripping automated endothelial keratoplasties (DSAEKs). Here, we present a case of endothelial graft rejection with an endothelial rejection line occurring 1 year after the procedure. CASE PRESENTATION: A 58-year-old female presented with graft rejection 1 year following a DSAEK procedure. The episode started when she tapered down her loteprednol to once a day. Slit-lamp examination showed a mildly injected conjunctiva with 1+ corneal oedema. On the posterior surface of the cornea, there was an endothelial rejection line (Khodadoust line) with keratic precipitates and multiple areas of anterior synechia. CONCLUSION: The classic endothelial rejection line should be kept in mind as a rare sign of DSAEK graft rejection.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: gold
Estimated APC paid: $2,170
OpenAlex ID: W3045644603
FWCI:
Cites: 13
Cited by: 2
Related to: 10