Experimental Research on the Hysteretic Behaviour of Pressurized Artificial Muscles Made from Elastomers with Aramid Fibre Insertions
Year: 2020
Type: article
Abstract: Inherent hysteresis behaviour of pressurized artificial muscles is complicated to understand and handle, calling for experimental research that allows the modelling of this phenomenon. The paper presents the results of the experimental study of the hysteretic behaviour of a small-size pneumatic muscle. The specific hysteresis loops were revealed by isotonic and isometric tests. Starting from hypothesis according to that the tube used for the pneumatic muscle is made entirely of aramid fibres enveloped by an elastomer material that merely ensures their airtightness, the paper presents the hysteresis curves that describe the radial and axial dimensional modifications as well as the variation of the developed forces for different feed pressures. The obtained third-degree polynomial equations underlie the configuration of high-performance positioning systems.
Source: Actuators
DOI: 10.3390/act9030083
Institution: Transilvania University of Brașov
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $1,056
OpenAlex ID: W3085644898