Work

Letter Report No. 14 Under Aec Contract At(30-1)-2298

Year: 1960
Type: report
Abstract: Data for the rate of hydrogen permeation through nickel with 0, 2, and 4% copper added, at 640 to 800 deg C and 1.1.to 2 atm pressure are given. The system of nickel with 1% copper developed a high-temperature leak and had to be dismantled. Graphs plotted with this data are also included. (M.C.G.)
Author: D.W. Rudd
Language: English
Open Access status: green
OpenAlex ID: W39939706
Cites:
Cited by:
Related to: 10