Indocyanine green colonic perfusion demonstration following robotic da Vinci X inferior mesenteric artery ligation for the treatment of type II endoleak
Year: 2022
Type: article
Study design: Case Report
Abstract: BACKGROUND: We describe the technical operative details of the robotic repair of a type II endoleak (T2E) following endovascular abdominal aortic aneurysm repair (EVAR). We demonstrate that indocyanine green (ICG) can be used intra-operatively to demonstrate perfusion of the colon following ligation of the inferior mesenteric artery (IMA) vessel feeding the aneurysm sac. METHODS: A 74-year old male underwent EVAR for a 5.8 cm infra-renal abdominal aortic aneurysm using an E-Tegra, Jotec Device (JOTEC Gmb, Lotzenäcker 23,D-72379 Hechingen). Surveillance contrast CT (CTA) over the ensuing 30 months confirmed progressive sac expansion. RESULTS: ICG confirmed colonic perfusion via the marginals after IMA ligation. Total operative time 56 min < 50 mls blood loss and 1-day hospital stay. 3-month follow-up: CTA and ultrasound demonstrated complete resolution of T2E and adequately perfused colon. CONCLUSION: A total robotic approach can be performed safely with intra-operative ICG used to demonstrate colonic perfusion as an added safety measure.
DOI: 10.1002/rcs.2407
Authors: Joel Lambert, Sulaymaan Al Majid, Robert Salaman, Duncan Gavan, Adnan Sheikh, Michael Gill
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,900