Work

A 200 kV fast rise time, low jitter, trigger system with magnetic pulse sharpener

Year: 1993
Type: report
Abstract: The DARHT Facility is being designed at Los Alamos National Laboratory to produce high resolution flash radiographs of hydrodynamic experiments. Two linear induction accelerators (LIA), each in the range of 16 to 20 MeV, will be used to produce intense bremsstrahlung X-ray pulses of short duration (60 ns flat top). Each LIA will produce a 3 kA, high brightness, electron beam using a 4 MeV injector and a series of 250 kV induction cells. Technology demonstration of key accelerator subsystems is under progress at the DARHT Integrated Test Stand (ITS). The eight inductions cells present in the ITS are driven by a Maxwell prototype Induction Cell Pulsed Power Supply (ICPPS) which provides 250 kV, 70ns pulses via four Blumleins. Each Blumlein drives two cells and is triggered using independently controlled trigger units. This turnkey DARHT Trigger System, consisting of four separate trigger units, provides 200 kV trigger pulses with low jitter and fast rise time to each of the four Blumlein coaxial spark gaps. Details of the trigger system design and results obtained during extensive testing at Maxwell are described.
Language: English
Open Access status: green
OpenAlex ID: W4230438987
Cites:
Cited by:
Related to: 10