Exposure of Titanium Mesh after Cranioplasty for Microvascular Decompression Surgery: Two Case Reports
Year: 2015
Type: article
Study design: Case Report
Abstract: Two cases of exposed titanium mesh occurred after implantation for cranioplasty after repeated procedures for microvascular decompression (MVD). Case 1 was a 62-year-old female who underwent MVD for left hemifacial spasm followed by repair of cerebrospinal fluid leak after the surgery, and Case 2 was a 75-year-old female who underwent MVD twice for right trigeminal neuralgia. Both patients visited our hospital again with complaints of postauricular lesion. Titanium mesh was visible through the operative scar and was successfully removed with no complication in both cases. Both patients were underweight females, and combined with multistep surgery may have contributed to the pathology. The present cases suggest that use of titanium mesh should be avoided for cranioplasty of posterior fossa surgery, especially for repeated procedures.
Source: NMC Case Report Journal
Institution: Mitsui Memorial Hospital
Language: English
Subfield: Clinical Neurology
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W4237189502