Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Year: 2022
Type: article
Abstract: Purpose Radionuclide irradiators ( 137 Cs and 60 Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. There are institutional initiatives to replace radionuclide sources with lower-energy X-ray sources amidst concerns of radiological terrorism. As researchers transition, there are questions whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays, since different energy may cause different biological effects. We, therefore, sought to compare the effects of orthovoltage X-rays and 137 Cs γ-rays using mouse models of acute radiation syndrome. Experimental Design 137 Cs γ-rays were compared with Orthovoltage X-rays, generated at 300 kVp, 10 mA with 1 mm Cu or Thoraeus filtration. We assessed 30-day overall survival following whole-body irradiation and calculated LD 50 by logistic regression. Comparing equivalent doses delivered with different average energies (Ē), we assessed bone marrow, spleen, and intestinal histology and flow cytometry. Results The LD 50 doses are 6.7 Gy, 7.4 Gy and 8.1 Gy with 1 mm Cu filtered (Ē=120 keV), and Thoraeus filtered X-rays (Ē=160 keV), and 137 Cs (E=662 keV), respectively. At constant dose, hematopoietic injury was most severe with 1 mm Cu filtered X-rays with the greatest reduction in bone marrow cellularity, stem and progenitor populations, and intestinal crypts and OLFM4 + intestinal stem cells. Thoraeus filtered X-rays provoked an intermediate phenotype, with 137 Cs showing the least damage. Conclusions Our study reveals a dichotomy between physical dose and biological effect relevant as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose-reduction to achieve comparable biological effects. Statement of Translational Relevance Radiation is used in translational studies in fields ranging from hematopoiesis and stem cell biology to cancer radiotherapy, with 137 Cs and 60 Co radionuclide sources serving as the most common irradiators. Due to the threat of radiological terrorism using stolen radionuclides, there are institutional initiatives to replace these sources with orthovoltage X-ray irradiators. Yet, as shown in this study, the biological effects of radiation are highly dependent on radiation energy. Lower energy orthovoltage X-rays are absorbed differently than higher energy radionuclide γ-rays, provoking more severe hematopoietic, immunologic, and gastrointestinal radiation injury. Thus, an identical physical dose delivered with beams of differing energy does not produce the same biologic effect. As researchers transition between these sources, it is critical that we appreciate that radiation doses are not interchangeable between them. Understanding the significance of physical dose delivered using different methods will allow us to contextualize past results with future studies.
Source: Cancer Research
Authors: Brett I. Bell, Justin Vercellino, N. Patrik Brodin, Christian Velten, Lalitha S.Y. Nanduri, Prashanth K.B. Nagesh, Kathryn E. Tanaka, Yanan Fang, Yanhua Wang, Rodney Macedo, Jeb English, Michelle M. Schumacher, Phaneendra K. Duddempudi, Patrik Asp, Wade Koba, Shahin Shajahan, Laibin Liu, Wolfgang A. Tomé, Weng-Lang Yang, Richard Kolesnick, Chandan Guha
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
Awards: Use of focused ultrasound to increase melanoma immunogenicity and inhibit tumor-induced T cell tolerance, G2106804487, G2141761845, Development of thrombopoietin mimetic (TPOm) as a mitigator against Radiation-induced endovascular injuries, High Speed, High Resolution Slide Scanner for Research in Translational Medicine, Stromal cell therapy as a treatment against Gastrointestinal Acute Radiation Syndrome (GI-ARS), G5898568995, Understanding stem cell heterogeneity and niche function in intestinal regeneration after irradiation, Cytek Aurora Multiparameter Flow Cytometer, G6975288514, High-speed/resolution whole slide scanner supported by two core facilities, Intestinal Stem Cell Consortium Coordinating Center, G872266094, Cancer Center Support Grant, Cancer Center Support Grant, Relative Immunological Effectiveness (RIE) of Carbon Ion Radiation Therapy for Pancreatic Cancer
OpenAlex ID: W4289517693
