Abstract: The current study concerns the use of azeotropic mixtures in single-stage vapor compression refrigeration system configurations to determine the effect of entrainment ratio on the coefficient of performance. Three singlestage vapor compression refrigeration system configurations are used. The effects of condenser and evaporator temperatures on the single-stage refrigeration system are investigated. The used azeotropic mixtures are: R1234yf + R290, R1234yf + R152a, R1234yf + R600a, R134a + R290, R134a + R600a and R1270 + R134a. It is shown that the simulations results are in good agreement with the literature. The R1234yf + R290 mixture in refrigeration cycle give the highest coefficient of performance and entrainment ratio. The coefficient of performance (COP) increases with increasing of entrainment ratio.