Abstract: Mass timber construction is an increasingly common way of building taller and larger wood buildings utilizing renewable building materials with lower embodied carbon.With a lighter mass and higher flexibility relative to concrete, however, a mass timber panel provides relatively poor acoustic separation between adjacent spaces.This poor acoustic performance combined with the desire for exposed mass timber ceilings means that an additional subfloor layer decoupled by an acoustic interlayer, is often used to provide adequate separation between spaces within the building.In some structural systems, screw fasteners through the acoustic interlayer maybe required.This study investigates the deterioration of the airborne and structure borne sound transmission performance due to the addition of metal fasteners through interlayer 304.8 mm, 609.6 mm and 1219.2 mm on centre (o.c.).The change to both the airborne and structure borne sound transmission is directly related to the spacing of the fasteners, with the most significant decrease in performance noted between 200-4000 Hz.This data provides insight into the performance of composite timber floor systems requiring fasteners through the resilient interlayer and will assist with designing these systems with more certainty in regard to the sound transmission that will occur within the building.