Work

Multilayer Perceptron Model Versus Charge Comparison Method for Neutron/Gamma Discrimination in Plastic Scintillator According to Sampling Frequency and Energy Radiation

Year: 2023
Type: article
Abstract: Pulse shape discrimination algorithms have been commonly implemented on embedded systems to discriminate neutron/gamma radiations detected by organic scintillators in several applications. These algorithms have a number of limitations, especially when used with plastic scintillators, which have low intrinsic discriminating ability. Machine learning (ML) models have recently been explored as a way to improve discriminating performance. Most of these methods are proposed for liquid and stilbene scintillators and do not address the integrated implementation. Reducing the sampling frequency of a discrimination system helps to minimize the size and cost of the embedded implementation. The purpose of this study is to explore whether the use of ML tools, compared to the tail-to-total integral ratio (TTTratio) algorithm, can lead to a reduction in the minimum required sampling frequency in EJ276 plastic scintillator, as well as an enhancement in the classification performance. The results obtained highlight the superior performance of the ML model.
Language: English
Subfield: Radiation
Open Access status: green
OpenAlex ID: W4384499137
FWCI: 1.357
Cites: 26
Cited by: 8
Related to: 10