Year: 2023
Type: article
Study design: Clinical Trial
Abstract: BACKGROUND: Patient-ventilator asynchrony is common in patients undergoing mechanical ventilation. The proportion of health-care professionals capable of identifying and effectively managing different types of patient-ventilator asynchronies is limited. A few studies have developed specific training programs, but they mainly focused on improving patient-ventilator asynchrony detection without assessing the ability of health-care professionals to determine the possible causes. METHODS: We conducted a 36-h training program focused on patient-ventilator asynchrony detection and management for health-care professionals from 20 hospitals in Latin America and Spain. The training program included 6 h of a live online lesson during which 120 patient-ventilator asynchrony cases were presented. After the 6-h training lesson, health-care professionals were required to complete a 1-h training session per day for the subsequent 30 d. A 30-question assessment tool was developed and used to assess health-care professionals before training, immediately after the 6-h training lecture, and after the 30 d of training (1-month follow-up). RESULTS: One hundred sixteen health-care professionals participated in the study. The median (interquartile range) of the total number of correct answers in the pre-training, post-training, and 1-month follow-up were significantly different (12 [8.75–15], 18 [13.75–22], and 18.5 [14–23], respectively). The percentages of correct answers also differed significantly between the time assessments. Study participants significantly improved their performance between pre-training and post-training ( P < .001). This performance was maintained after a 1-month follow-up ( P = .95) for the questions related to the detection, determination of cause, and management of patient-ventilator asynchrony. CONCLUSIONS: A specific 36-h training program significantly improved the ability of health-care professionals to detect patient-ventilator asynchrony, determine the possible causes of patient-ventilator asynchrony, and properly manage different types of patient-ventilator asynchrony.
Source: Respiratory Care
Institutions: Instituto Nacional del Tórax, Hospital Clínico de la Universidad de Chile, Universidad Diego Portales, Universidad Andrés Bello, Pontificia Universidad Católica de Chile, Universidad Autónoma de Chile, Universidade Estadual de Ciências da Saúde de Alagoas, Hospital Italiano de Buenos Aires, National University Toribio Rodríguez de Mendoza, Hospital la Serena, Universidad Francisco de Vitoria, Instituto de Salud Carlos III, Centro de Investigación Biomédica en Red de Enfermedades Respiratorias, Hospital Universitario del Henares, Universitat Autònoma de Barcelona, Corporació Sanitària Parc Taulí, Institute of Research and Innovation Parc Tauli
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W4389099484