Work

Monitoring of Battery Energy for Hybrid PLTS and Picohydro Systems on Water Pumps

Year: 2024
Type: book-chapter
Abstract: The use and utilization of renewable energy must continue to be developed both in terms of science, human resource skills and its application in society.The use of solar energy as an alternative energy to generate electricity has been widely applied.One of them is to turn on a 250 Watt, 12 Volt submersible DC water pump.The author uses a 400 Wp solar panel.The output water discharge from the pump is used to drive a 150 Watt DC picohydro generator.Research conducted in 2 hours, the energy generated during the charge and discharge process of the Lithium Iron Phosphate Battery (LiFePO4) 100 Ah at the same time compared to the process of charging and discharging the battery at different times produces an average energy (320: 172.6 Wh (charge); 168.4: 152 Wh (discharge)) and an average capacity (24.58: 12.34 Ah (charge); 12.12: 11.65 Ah (discharge)).While the average ratio of SOC (State of Charge) is (88: 100% (charge)); (88: 57.5 % (discharge)).While the average of water generated during the discharge process (1374.25:1333.81 liter/hour) and the output voltage of the picohydro generator (4.37: 4.195 Volts).It can be concluded that the average energy and SOC generated in the process of charging and discharging the battery at the same time is better.The electric voltage generated by the picohydro generator by utilizing the water discharge output is still relatively small, less than 12 volts.
Language: English
Field: Energy
Open Access status: hybrid
OpenAlex ID: W4391852017
FWCI:
Cites: 2
Cited by:
Related to: 10