Theoretical investigation of dosimeter accuracy for linear energy transfer measurements in proton therapy: A comparative study of stopping power ratios
Year: 2024
Type: article
Abstract: Background Accurate measurement of linear energy transfer (LET) is crucial in medical physics , particularly for proton therapy dosimetry . High atomic-number ( Z e f f ) materials such as BaFBr and low- Z e f f materials such as A l 2 O 3 and water are commonly used in dosimeters. Purpose To evaluate the feasibility and accuracy of the use of various dosimetry materials (water, air, A l 2 O 3 , aluminum (Al), BaFBr, and oxygen) for measuring LET by comparing their stopping power (ratios) via the Bethe-Bloch theory and semiempirical models. Methods Stopping power ratios were calculated via the PSTAR database for proton energies ranging from 0.01 MeV to 10,000 MeV. The Bethe-Bloch theory with density and shell corrections was used for high-energy protons, whereas a semiempirical model was applied for low-energy protons. Calculations validation involved comparing the computed stopping powers SRIM-2008 and PSTAR for materials such as water, aluminum, air, A l 2 O 3 , BaFBr, and oxygen. Results The stopping power water-to-air ratio remains stable, while the A l 2 O 3 -to-water and air-to-water ratios highlight their differing attenuation properties. The BaFBr-to-water ratio shows significant material-dependent differences, and the water-to- A l 2 O 3 ratio is particularly relevant for proton therapy dosimetry calculations in medical physics. These results demonstrate consistency across materials but do not inherently confirm the accuracy of LET measurements. However, a comparison of theoretical models with computed stopping powers SRIM-2008 and PSTAR showed strong agreement, particularly for high-energy protons where the Bethe-Bloch theory was applied, suggesting that the models reliably predict stopping power at these energy levels. Conclusions This study confirms the feasibility of using high- Z e f f materials such as BaFBr and low- Z e f f materials such as A l 2 O 3 and water for the use of LET measurements in proton therapy. The results validate the use of the Bethe-Bloch theory, computed stopping powers and semiempirical models in dosimetric applications, enhancing the precision of LET measurements and contributing to improved radiation therapy outcomes.
Source: Radiation Physics and Chemistry
Author: Johnpaul Mbagwu
Institution: University of Kansas
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $3,730
OpenAlex ID: W4403961982
