Comparison of human smartwatch and transmittance pulse oximetry for evaluating peripheral oxygen saturation in anesthetized dogs.
Year: 2024
Type: article
Abstract: Background: Pulse oximetry is a valuable tool for monitoring animals during anesthesia and assessing the adequacy of administered oxygen therapy. Aims: To compare the pulse oximeter readings obtained by the Garmin Fenix 5X plus (GF5Xp) smartwatch and transmittance pulse oximetry (TPO) in anesthetized dogs. Methods: (Gold standard - Device), and the limits of agreement were represented as the mean ± 1.96 times the standard deviation. Results: levels in dogs were overestimated by the GF5Xp relative to the readings obtained by the TPO, with the bias of -0.3% (95% CI: -3.1%-2.5%). Conclusion: GF5Xp may be interchangeable with TPO in dogs. Further studies are required to validate the accuracy of the GF5Xp in non-anesthetized dogs or dogs outside the physiological range.
Source: PubMed Central
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W4405028700