Effectiveness and clinical impact of using deep learning for first-trimester fetal ultrasound image quality auditing
Year: 2025
Type: article
Abstract: BACKGROUND: Regular auditing of ultrasound images is required to maintain quality; however, manual auditing is time-consuming and can be inconsistent. We therefore aimed to develop and validate an artificial intelligence-based image quality audit (AI-IQA) system to audit images from the four key planes used in first-trimester scanning. METHODS: The AI-IQA system was developed based on the YOLOv7 structure detection network and a multi-branch image quality regression network using a large multicenter internal dataset. Clinical validation was performed using 567 cases scanned by four radiologists with different experience levels, of which 349 were performed without AI-IQA feedback (clinical test set 1) and 218 were performed after 2-3 rounds of AI-IQA feedback (clinical test set 2). The proportion of standard images obtained and detailed expert audit results were compared to verify whether AI-IQA could objectively and accurately provide feedback on deficiencies in nonstandard images to assist radiologists at different experience levels in improving image quality. RESULTS: In the internal test set, the AI-IQA system achieved high average accuracy precision, recall and F1-score in auditing the overall plane quality (0.881, 0.833, 0.842 and 0.837, respectively) and structure quality (0.906, 0.861, 0.857 and 0.859, respectively). In clinical test sets 1 and 2, AI-IQA results showed strong consistency with expert assessment results, with the average Cohen's Kappa coefficient exceeding 0.8 for all four planes. In addition, following AI-IQA feedback, the proportion of standard images obtained by junior and mid-level radiologists increased by 7.7% and 5.1%, respectively. AI-IQA takes only 0.05 s to assess each image, while experts require more than 20 s (p < 0.001). CONCLUSIONS: The proposed AI-IQA system proved to be a highly accurate and efficient method of automatically auditing first-trimester scanning image quality, providing precise and rapid key plane quality control. This tool can also assist radiologists with different levels of experience to improve the image quality.
Source: BMC Pregnancy and Childbirth
Authors: Xiaoyan Cao, Binghan Li, Yongsong Zhou, Yan Cao, Xin Yang, Xindi Hu, Chaoyu Chen, Shaokao Zhu, Hengli Lin, Tao Wang, Yuling Yan, Tao Tan, Lin Wang, Dong Ni
Language: English
Subfield: Health Informatics
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,290
OpenAlex ID: W4408995552