Interfacial properties determine the performance of embedded IrOx pH sensor in cement mortar
Year: 2025
Type: article
Abstract: IrO x electrode has been reported to show promising application in pH determination in many environments. Once embedded in cement mortar , the performance of IrO x electrode is poor. The failed pH determination is due to inaccurate potential measurement of embedded IrO x electrodes, including potential difference across aqueous solution/mortar interface ( E 1 ), potential difference generated due to transport of charge carriers in pore structure of cement mortar ( E 2 ), and potential difference across interfacial transition zone (ITZ)/IrO x electrode interface ( E 3 ). E 1 is measured to be 19.6 mV, leading to a lower calculated pH by 0.39. E 2 is 20.9 mV, indicating E 2 associated error in pH determination is also minor (0.42 pH). E 3 (of −317.3 mV) is confirmed to introduce serious errors in potential measurement, due to excessive resistance across the ITZ area. The microstructure of ITZ is studied by X-ray computed tomography (μXCT). In the case of OPC , abnormal porosity is observed. Although the continuous pores can't be detected by μXCT, it is proposed the presence of abundant continuous pores is essential for a meaningful measurement of the IrO x electrode potential and the subsequent calculation of pH in pore water.
Language: English
Subfield: Analytical Chemistry
Field: Chemistry
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $1,640
OpenAlex ID: W4409537726