Work

Development of Several Workflows for the Cryo-FIB/TEM

Year: 2025
Type: article
Abstract: Cryo transmission electron microscopy (TEM) provides structural information of biological macromolecules close to their natural state without any disturbance during the sample preparation process. Recently, cryo TEM can achieve high resolution results in combination with the methods of single particle analysis (SPA) and cryo electron tomography (cryo-ET) [1]. Especially, cryo-ET is widely known as a well-established technique for analyzing the structural details of macromolecular complexes and organelles in the cells. Cryo-ET usually handle with thicker samples than those for SPA because the target of cryo-ET is mainly cells while the target of SPA is mainly purified protein particles. Quite recently, the desire to analyze macromolecular complexes within their cellular context has been increasing. It requires the ability to produce thin specimens from thick cells or tissues suitable for cryo-TEM. Cryo-FIB are rapidly evolving as a tool for preparing thin specimens for this purpose [2]. We introduce several workflows for the cryo-FIB/TEM. The workflows use a cartridge for CRYO ARMTM and a CryoLamellar system which is equipped with SEM observation function (Fig. 1). The CryoLameller system features a cryo-transfer holder which can hold a cartridge for CRYO ARMTM, a platinum coater which is equipped in the sub-chamber, a proprietary anti-contamination system, and a stage with high stability and flexibility. These features could reduce the number of sample transfer step, then it leads to minimize the risk of ice contamination and to improve the success rate of sample observation. In details for the basic on-the-grid lamella workflow to observe single cell specimen, the cartridge with a plunge frozen grid is set into the tip of a dedicated holder in the cryo workstation. Since the FIB-SEM, which is equipped with a cryo stage, was used for the workflow, it is also possible to observe the detail of the milling position by SEM. After FIB processing, the cartridge was removed from the holder, loaded into a magazine, and transferred to the CRYO ARMTM using a transfer cup for cryo TEM observation. As a result of using dedicated cartridges, no sample rotation between different instruments through our workflows is also significantly advantageous for tomography. On the other hand, sample preparation for the tissue samples thicker than 10 μm is challenging because cryo-ET samples must be rapidly frozen to prevent the formation of ice crystals. Therefore, high-pressure freezing (HPF) is used to freeze thick samples rapidly. Cryo lift-out method [3] is needed to be used for extracting thin lamella from this frozen tissue specimen. For the cryo lift-out workflow, we developed a dedicated cartridge which can mount HPF sample carrier with a diameter of 3 mm (Fig. 2). A block is extracted from a bulk sample on the carrier and picked up with a cooled manipulator. The extracted block can be transferred and attached onto a half-moon grid with the manipulator. Polishing process to finalize the thin lamella is done on the grid. After FIB processing, the cartridge can be transferred to the CRYO ARMTM with a same scheme as the on-the-grid lamella workflow. Recently, several cryo-correlative microscopies have been reported [4], in which the labeled biological samples are observed with cryo-fluorescence microscopy, and the labeled sites are observed with cryo-TEM after the FIB milling process. We introduce developing workflows of cryo-correlative light and electron microscopy (cryo-CLEM) with the cartridge and a dedicated cryo stage for a light microscope which can mount the cartridge. The schematic illustration of the cryo FIB/TEM workflow. The schematic illustration of the dedicated cartridge for the cryo lift-out workflow.
Authors: Naoki Hosogi, Rintaro Kawano, Hideki Matsushima, Chikako Nakayama, Noriaki Mizuno
Institution: JEOL (Japan)
Language: English
Open Access status: bronze
OpenAlex ID: W4412909183
FWCI:
Cites: 4
Cited by:
Related to: 10