Work

Ductility and resistance of bolted connections in structures made of high strength steels

Year: 2008
Type: dissertation
Abstract: Structural steel grades with yield strength higher than 420 MPa are considered as high strength steels. They undoubtedly have lower ductility than mild steels in terms of engineering measures of ductility, such as ultimate-to-yield strength ratio, uniform strain and elongation at fracture. A typical values for high strength steels are: ultimate-to-yield strength ratio fu/fy = 1,05, uniform strain εu = 0,05 and elongation after fracture εfr = 15%. The problem is that inelastic behaviour is hidden in numerous nominally elastic resistances checks of steel structures and therefore sufficient local ductility has to be assured. The focus is set on structural elements with holes subjected to tension and to tension splices with bolts in shear. Local ductility in terms of plastic deformations has to be sufficient in order to assure bolthole elongation, so the loading transfers through all bolts. An extensive experimental research of plates with holes and tension splices made of steel grade S690 was conducted to determine maximum resistance and ductility. The reliability of the Eurocode design rules for net cross- section resistance to was statistically evaluated. The statistical analysis was substantiated by additional test results on net cross-section failure of high strength steel members available in literature. Moreover, the experiments were numerically simulated to look inside the stress state. The test results served as a guideline for the accuracy of numerical simulations. A comprehensive numerical parametrical study of tension splices and in addition, the numerical analyses of tests on tension splices found in literature were performed. The Eurocode design bearing resistance was critically assessed on the basis of the database of 266 connection results. In certain cases the Eurocode design bearing resistance formula gives inadequate results. Therefore, a new, simple design bearing resistance formula was proposed.
Language: English
Open Access status: green
OpenAlex ID: W4903215
Cites:
Cited by: 2
Related to: 9