Work

Comparison of Densiron 68 and 1 000 cSt silicone oil in the management of rhegmatogenous retinal detachment with inferior breaks.

Year: 2013
Type: article
Abstract: AIM: To compare success rates and complications of Densiron 68 and 1000cSt silicone oil (SO) in the management of rhegmatogenous retinal detachment (RRD) with inferior breaks (IBs). METHODS: Totally 61 eyes of 61 consecutive patients with RRD with IBs were assigned to pars plana vitrectomy (PPV) with Densiron (n=31) or PPV with SO (n=30) in order of presentation. SO and Densiron removal was performed 3 months after initial surgery. Follow up visits were terminated 6 months after SO removal. RESULTS: With a single operation, the Densiron group showed 84% and SO 74% reattachment. With further surgery, both groups showed 90% re-attachment. Complications such as cataract, raised intraocular pressure (IOP), inflammatory reaction, macular epiretinal membranes, and emulsification of SO were seen in both groups. CONCLUSION: Densiron and SO are found to have similar success rates and complications.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: green
OpenAlex ID: W49975500
FWCI: 1.407
Cites:
Cited by: 25
Related to: 10