Work

Total organic carbon (TOC) and chemical oxygen demand (COD) - Monitoring of organic pollutants in wastewater

Year: 2011
Type: dissertation
Abstract: Total organic carbon (TOC) and chemical oxygen demand (COD) are two methods used for measuring organic pollutants in wastewater. Both methods are widely used but the COD method results in production of hazardous wastes, including mercury.The purpose of this study was to validate the method TOC that will replace COD and find a factor to convert TOC to COD. In this study 26 samples were analyzed from four sewage treatment plant in the municipality of Enköping.The results show that the COD method could be replaced by the TOC method.The factor for COD/TOC was between 3.1 - 3.3. Both methods will be used in parallel until 2013 when it will be forbidden to use the COD analysis.
Language: English
Open Access status: green
OpenAlex ID: W601201360
Cites: 14
Cited by: 2
Related to: 10