An Ultrasonic Thermometry System for measuring very high temperatures in reactor safety experiments
Year: 1979
Type: report
Abstract: are described. In them, five 10-mm-length sensor elements were used to measure axial temperatures in a UO/sub 2/ or UO/sub 2/-steel system fission-heated to about 2860/sup 0/C.
DOI: 10.2172/12177640
Authors: DOE, Gary Carlson, William Sullivan
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green