Work

An Ultrasonic Thermometry System for measuring very high temperatures in reactor safety experiments

Year: 1979
Type: report
Abstract: are described. In them, five 10-mm-length sensor elements were used to measure axial temperatures in a UO/sub 2/ or UO/sub 2/-steel system fission-heated to about 2860/sup 0/C.
Language: English
Open Access status: green
OpenAlex ID: W61434611
Cites:
Cited by: 10
Related to: 10