Abstract: This report discusses a TRAC model of the Westinghouse AP600 advanced reactor design which has been developed for analyzing large-break loss-of-coolant accident (LBLOCA) transients. A preliminary LBLOCA calculation of a 80% cold-leg break has been performed with TRAC-PF1/MOD2. The 80% break size was calculated by Westinghouse to be the most severe large-break size. The LBLOCA transient was calculated to 92 s. Peak clad temperatures (PCT) were well below the Appendix K limit of 1478 K (2200{degrees}F). Transient event times and PCT for the TRAC calculation were in reasonable agreement with those calculated by Westinghouse using their WCOBRA/TRAC code.
Language: English
Field: Energy
Open Access status: green
OpenAlex ID: W66979439
FWCI:
Cites:
Cited by: 3
Related to: 10