Day 4 patch test results to the British Society for Cutaneous Allergy (BSCA) standard series, BSCA methacrylate series and medical device series

Year: 2025
Type: other
Abstract: Continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) devices are essential tools for diabetes management but are increasingly associated with allergic contact dermatitis (ACD). Since 2015, allergens such as isobornyl acrylate (IBOA) and colophonium derivatives have been implicated in device-related dermatitis. However, manufacturers often do not disclose allergen content, complicating diagnosis.We investigated 18 patients referred with suspected ACD to CSII or CGM. All were patch tested using the British Society for Cutaneous Allergy (BSCA) standard and methacrylate series, as well as a non-commercially available medical device series. Additional testing included direct application of patient dressings and scrapings from device plastics. Patch tests were read on days 4 and 7. Separately, six CGM/CSII devices underwent gas chromatography–mass spectrometry (GC/MS) analysis.Twelve patients had positive reactions to devices or adhesives. Colophonium derivatives were the most frequent allergens, with ten patients reacting to methyl hydrogenated rosinate, glyceryl hydrogenated rosinate, and/or colophonium 60%, although only four were detected using standard colophonium 20% testing. Three patients had positive reactions to IBOA, and others reacted to methacrylate derivatives such as hexanediol diacrylate and N,N-dimethyl acrylamide. Co-reactivity to fragrance terpenes was observed, aligning with previous reports of increased fragrance sensitivity in this population.GC/MS confirmed the presence of IBOA in Freestyle Libre 1™, Libre 2™, Medtronic Guardian Sensor 3™, and Dexcom G7™ devices. Colophonium-related methyl dehydroabietate was detected in Guardian Sensor 3™ and Dexcom G7™ adhesives.Our findings highlight the limitations of standard patch testing in detecting device-related allergens. Diagnosis was improved by including non-commercial allergen preparations and testing components from patients’ own devices. Accurate diagnosis of diabetes technology-associated ACD requires collaboration with specialist laboratories and more transparency from manufacturers regarding allergen content.
Source: Figshare
Author: Sexton, Fiona
Language: English
Subfield: Dermatology
Field: Medicine
Open Access status: green
OpenAlex ID: W6976965151
Cites:
Cited by:
Related to: 10